Sign in
United Kingdom › MYP Biology › Organisms and life processes
Question

Closed-Loop Insulin Systems

A2 · D18 · 20 marks · ~26 min
✦ Created by our AI question engine · answers checked by script Self-marked 0 / 9
How this page works Full help
  1. Read the question and the information above the parts.
  2. Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
  3. Check your final line with Check my answer. Use the calculator on the right when you need it.
  4. Mark yourself: open the markscheme and tick each mark you earned.

In type 1 diabetes, the immune system destroys the cells in the pancreas that make insulin, so people must take insulin for the rest of their lives. A newer treatment links a glucose sensor to an insulin pump so that a computer program adjusts the insulin dose automatically. In December 2023, NICE recommended these systems for many people with type 1 diabetes, and from April 2024 the NHS in England began a five-year roll-out, starting with children and young people.

Source A (an explainer written for this question) A small sensor under the skin of the arm or abdomen measures the glucose concentration of the tissue fluid every few minutes. It sends the reading to a program in the insulin pump or a phone. The program raises or lowers the amount of insulin the pump delivers through a thin tube under the skin. The system is called hybrid closed-loop because the user still has to tell it when they are about to eat a meal.

Source B (data written for this question, for one diabetes clinic with 120 patients, before and after 6 months on the system)

MeasureBeforeAfter 6 months
Mean time with blood glucose in the target range (3.9–10 mmol/dm³)52%71%
Mean time with blood glucose below 3.9 mmol/dm³ (too low)4%2%
Severe low-glucose episodes needing help from another person, whole clinic, per year156

Source C (figures written for this question) Compared with insulin injections and finger-prick blood tests, the pump, sensors and supplies cost the NHS about £3000 more per patient each year. Long-term high blood glucose damages small blood vessels in the eyes, kidneys and feet; treating these complications costs the NHS a large amount every year.

Source D (a view written for this question) Maya, aged 15: "I sleep through the night now, and my parents don't come in to check on me at 3 a.m. But the sensor has come off twice in PE, the alarm went off in a mock exam, and the tape makes my skin itchy."

Source E (a view written for this question) Mr Adeyemi, a diabetes nurse: "It is the biggest change I have seen in twenty years. But every patient needs training, and we do not have enough staff to train everyone at once. A blocked tube can stop insulin without the user noticing, so people must still carry an insulin pen and know what to do."

60.1
A2 Level 1–2
[2]Sort these events to show how the body of a person without diabetes responds after a meal rich in carbohydrate.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Glucose is absorbed into the blood; the pancreas detects the rise; it releases insulin; liver and muscle cells take in glucose and store it as glycogen; blood glucose falls back to normal. This is negative feedback.
e, c, d, a, b

Mark yourself

60.2
D2 Level 3–4
[2]The closed-loop system copies the body's own control system. Drag each part of the system to the job it does in the body. One part is not used.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

The sensor detects glucose (receptor role), the program decides the dose (coordinator role) and the pump delivers insulin (effector role). The tape only holds the sensor in place.
t1 sensor, t2 program, t3 pump

Mark yourself

60.3
D2 Level 3–4
[2]Use Source B. Calculate how many extra hours per day, on average, a patient's blood glucose is in the target range after 6 months on the system. Give your answer to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Increase in time in range = 71% − 52% = 19 percentage points. Extra time = 0.19 × 24 h = 4.56 hours per day.
4.56 hours per day

Mark yourself

60.4
D2 Level 5–6
[2]Use Source C. The clinic's 120 patients all use the system. Calculate the extra cost to the NHS per year for each severe low-glucose episode prevented at this clinic (Source B). Give your answer to the nearest £1000.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Extra cost = 120 × £3000 = £360 000 per year. Episodes prevented = 15 − 6 = 9. Cost per episode prevented = 360 000 ÷ 9 = £40 000.
£40 000

Mark yourself

60.5
D2 Level 5–6
[2]Select two reasons why the cost per episode prevented, calculated in the previous part, makes the system look less good value than it really is.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

The calculation counts only severe low-glucose episodes. It ignores the long-term savings from fewer complications caused by high glucose (Source C) and benefits such as better sleep and less worry for families (Source D).
a and c

Mark yourself

60.6
D10 Level 7–8
[10]Discuss and evaluate whether the NHS should offer hybrid closed-loop systems to everyone with type 1 diabetes as quickly as possible. In your answer you should: - explain how the system helps to control blood glucose, using your knowledge of insulin - consider at least two types of factor (for example economic, social, ethical) - use evidence from at least three named sources - give arguments for and against - finish with a justified conclusion.
Markscheme · 10 marks

Model answer

A hybrid closed-loop system does the job of the pancreas cells that are destroyed in type 1 diabetes. The sensor detects the glucose concentration of tissue fluid every few minutes (Source A), and the program raises or lowers the insulin dose. Insulin makes liver and muscle cells take in glucose and store it as glycogen, so blood glucose falls; with less insulin it rises again. Because the dose is adjusted constantly, glucose stays in the target range for longer. Source B supports this: time in range rose from 52% to 71%, about 4.6 extra hours each day, time with low glucose halved and severe episodes fell from 15 to 6 a year. Socially, Maya (Source D) sleeps through the night and her parents worry less. Economically, the system costs about £3000 more per patient each year (Source C), which is £360 000 a year for this clinic, or about £40 000 for each severe episode prevented. However, this ignores the savings from fewer complications in the eyes, kidneys and feet, which are expensive to treat. On the other hand, there are problems. Sensors can come off and alarms can be disruptive (Source D), and Mr Adeyemi (Source E) warns that a blocked tube can stop insulin without the user noticing, so everyone needs training and a back-up pen. There are not enough staff to train everyone at once, so rushing could be unsafe. There is also an ethical question of fairness: if some areas get the system years before others, access depends on where you live, and some people may not want to wear a device at all. In conclusion, the NHS should offer the system to everyone with type 1 diabetes who wants it, because the health benefits are large and long-term savings may cover much of the cost, but not all at once. It should be introduced in stages, starting with children and people with frequent severe lows, while enough nurses are trained to support each patient safely.
Solves
0
Average rating
–
Open reports
0

Assessment criteria

A
Knowing and understanding
B
Inquiring and designing
C
Processing and evaluating
D
Reflecting on the impacts of science

Quality checks

  • Created by our AI question engine
  • Every number checked by script
  • Published for students