✦ Created by our AI question engine · answers checked by script
Self-marked 0 / 9
How this page works
Full help
- Read the question and the information above the parts.
- Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
- Check your final line with Check my answer. Use the calculator on the right when you need it.
- Mark yourself: open the markscheme and tick each mark you earned.
A class tests three pieces of glassware by using each to measure out 25.00 cm³ of water four times. Each portion is weighed on a balance reading to 0.01 g. Taking the density of water as 1.00 g/cm³ (the true value at room temperature, 0.998 g/cm³, is slightly lower, but the class ignores this), the mass in grams is used as the volume delivered in cm³.
| Glassware | Portion 1 (cm³) | Portion 2 (cm³) | Portion 3 (cm³) | Portion 4 (cm³) | Mean (cm³) |
|---|---|---|---|---|---|
| 50 cm³ measuring cylinder | 24.10 | 25.60 | 24.90 | 25.80 | 25.10 |
| burette | 25.02 | 24.98 | 25.01 | 24.99 | 25.00 |
| an old 25 cm³ pipette | 24.62 | 24.60 | 24.61 | 24.61 | see part 117.6 |
117.1
[1]Select the piece of glassware designed to deliver one fixed volume, such as exactly 25.00 cm³, most precisely.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
A volumetric pipette has a single line and delivers one fixed volume, such as 25.00 cm³, with a very small uncertainty.
Option d.
Mark yourself
117.2
[1]Select the correct way to read the volume in a burette.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
Read the bottom of the meniscus with your eye level with it, to avoid parallax error.
Option b.
Mark yourself
117.3
[2]In a titration, a burette reads 0.35 cm³ at the start and 24.80 cm³ at the end. Each reading has an uncertainty of ±0.05 cm³, and the titre is found from two readings, so the titre has an uncertainty of ±0.10 cm³. Calculate the percentage uncertainty in the titre. Give your answer to 2 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Titre = 24.80 − 0.35 = 24.45 cm³. Uncertainty = 2 × 0.05 = ±0.10 cm³. Percentage uncertainty = 0.10 ÷ 24.45 × 100 = 0.409% = 0.41%
0.41%
Mark yourself
117.4
[1]Select the glassware whose results were precise but not accurate.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
Precise results agree closely with each other; accurate results are close to the true value. The old pipette's portions (24.60 to 24.62 cm³) agree within 0.02 cm³ but are all about 0.4 cm³ below 25.00 cm³: precise but not accurate.
Option a.
Mark yourself
117.5
[2]A student suggests measuring 20 more portions with the old pipette to make its result more accurate. Explain why this would not help.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
The old pipette has a systematic error: every portion is about 0.4 cm³ too small, in the same direction (perhaps its tip is chipped or it was calibrated wrongly). Repeating and averaging only reduces random errors, so the mean of 20 more portions would still be about 0.4 cm³ too low.
It is a systematic error (every portion low by the same amount); repeats and averaging only reduce random error.
Mark yourself
117.6
[2]Calculate the size of the percentage error (ignore its sign) in the mean volume delivered by the old pipette, compared with the true value of 25.00 cm³. Give your answer to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Mean = (24.62 + 24.60 + 24.61 + 24.61) ÷ 4 = 24.61 cm³. Error = 25.00 − 24.61 = 0.39 cm³. Percentage error = 0.39 ÷ 25.00 × 100 = 1.56%
1.56%
Mark yourself
117.7
[3]A student claims: "The measuring cylinder is just as good as the burette for measuring 25.00 cm³, because both means are within 0.1 cm³ of the true value." Evaluate this claim using the data in the table.
Markscheme · 3 marks
Model answer
The means alone make the claim look reasonable: 25.10 cm³ for the cylinder and 25.00 cm³ for the burette are both close to the true value. But the spread tells a different story. The cylinder's four portions ranged from 24.10 to 25.80 cm³, a range of 1.70 cm³, while the burette's ranged only from 24.98 to 25.02 cm³, a range of 0.04 cm³, about 40 times smaller. The cylinder's mean is close only because large random errors above and below the true value happened to cancel out. In real work a volume is usually measured once, and a single cylinder portion could be almost 1 cm³ out. So the claim is wrong: the burette is far better for measuring 25.00 cm³, although a measuring cylinder is fine when only a rough volume is needed.