Sign in
United Kingdom › MYP Chemistry › Investigating in chemistry
Question

Copper Plating and the Size of the Current

A1 · B6 · C5 · 12 marks · ~17 min
✦ Created by our AI question engine · answers checked by script Self-marked 0 / 9
How this page works Full help
  1. Read the question and the information above the parts.
  2. Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
  3. Check your final line with Check my answer. Use the calculator on the right when you need it.
  4. Mark yourself: open the markscheme and tick each mark you earned.

Ji-woo investigates how the current affects the mass of copper deposited during electrolysis. She uses two copper electrodes in copper(II) sulfate solution, connected to a power supply, an ammeter and a variable resistor. At the negative electrode (cathode), copper ions gain electrons and copper metal is deposited:

$\mathrm{Cu^{2+}(aq) + 2e^{-} \rightarrow Cu(s)}$

Method. Ji-woo cleans and weighs the cathode, passes a current for exactly 20 minutes, then removes the cathode, rinses it with distilled water, dries it and weighs it again. She uses a new 100 cm³ portion of the same solution for each run. Her results were written for this question but are in a realistic range.

Current (A)0.200.400.600.801.00
Increase in mass of cathode (g)0.0780.1570.2050.3140.392

Data you need

QuantityValue
relative atomic mass of Cu63.5
62.1
B2 Level 1–2
[2]Drag each quantity to the type of variable it is in Ji-woo's investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Ji-woo chooses the current (independent), measures the increase in mass (dependent) and keeps the time at 20 minutes (control).
current independent; mass increase dependent; time control

Mark yourself

62.2
B1 Level 1–2
[1]Select the reason Ji-woo dries the cathode before weighing it at the end of each run.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark

Model answer

Any water left on the cathode would be weighed as well, making the increase in mass seem larger than the mass of copper deposited.
Water left on it would add to the mass.

Mark yourself

62.3
C1 Level 3–4
[1]Select the current that gave an anomalous result.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark

Model answer

The other results increase by about 0.078 g for every 0.20 A. The result at 0.60 A, 0.205 g, is well below the value this pattern predicts, so it does not fit.
0.60 A

Mark yourself

62.4
C2 Level 5–6
[2]The mass deposited is directly proportional to the current. Use the result at 1.00 A to calculate the mass of copper Ji-woo should have deposited at 0.60 A. Give your answer to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Mass is proportional to current, so mass at 0.60 A = 0.392 × 0.60 ÷ 1.00 = 0.2352 = 0.235 g
0.235 g

Mark yourself

62.5
A1 · C2 Level 7–8
[3]Calculate the amount, in moles, of electrons that passed through the circuit in the 1.00 A run. Use the half-equation and give your answer to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks

Model answer

Moles of copper = 0.392 ÷ 63.5 = 0.006 173 mol. Each copper ion gains 2 electrons, so moles of electrons = 2 × 0.006 173 = 0.012 35 = 0.0123 mol
0.0123 mol

Mark yourself

62.6
B3 Level 7–8
[3]Suggest two possible causes of the anomalous result and explain how Ji-woo could improve her method to make her results more reliable.
Markscheme · 3 marks

Model answer

The mass at 0.60 A is too low. One possible cause is that some of the copper deposit flaked off when Ji-woo rinsed or dried the cathode; she could rinse it gently and dry it in warm air without wiping it. Another possible cause is that the current fell below 0.60 A during the run, for example as the electrodes changed; she should watch the ammeter throughout and adjust the variable resistor to keep the current constant. Finally, she should repeat each current three times and calculate a mean, so that an anomaly like this can be identified and left out, making her results more reliable.
Solves
0
Average rating
–
Open reports
0

Assessment criteria

A
Knowing and understanding
B
Inquiring and designing
C
Processing and evaluating
D
Reflecting on the impacts of science

Quality checks

  • Created by our AI question engine
  • Every number checked by script