Sign in
United Kingdom › MYP Chemistry › Organic chemistry
Question

Cracking Paraffin in a Virtual Lab

B8 · C10 · 18 marks · ~24 min
✦ Created by our AI question engine · answers checked by script Self-marked 0 / 9
How this page works Full help
  1. Read the question and the information above the parts.
  2. Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
  3. Check your final line with Check my answer. Use the calculator on the right when you need it.
  4. Mark yourself: open the markscheme and tick each mark you earned.

Cracking breaks long-chain alkanes into shorter alkanes and alkenes. For example, decane can crack like this:

$\mathrm{C_{10}H_{22}(g) \rightarrow C_8H_{18}(g) + C_2H_4(g)}$

In school, paraffin (a mixture of long-chain alkanes) is heated in a boiling tube and its vapour is passed over hot aluminium oxide, a catalyst. The short-chain products are gases. Eszter uses a virtual-lab simulation of this experiment (described here; it was written for this question). She can choose the temperature of the catalyst from 300 °C to 700 °C, the mass of catalyst and the size of its pieces. The gas is collected in a 100 cm³ gas syringe, and the simulation reports the volume after 120 s. It adds small random variations, as a real experiment would.

The graph shows the simulation's plot of the volume of gas against time for one extra run, with the catalyst at 650 °C.

0 20 40 60 80 100 120 0 10 20 30 40 50 60 70 80 90 100 Time (s) Volume of gas collected (cm³)
Volume of gas collected against time with the catalyst at 650 °C.
94.1
B1 Level 1–2
[1]Select the best research question for Eszter's investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark

Model answer

How does the temperature of the aluminium oxide catalyst affect the volume of gas collected in 120 s? It names the independent variable (catalyst temperature) and the dependent variable (gas volume in a fixed time).
Option c.

Mark yourself

94.2
B1 Level 1–2
[1]Select the correct independent and dependent variables for Eszter's investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark

Model answer

Eszter changes the catalyst temperature (°C) and measures the volume of gas collected in 120 s (cm³).
Option b.

Mark yourself

94.3
B2 Level 3–4
[2]Write a hypothesis for Eszter's investigation. Give a prediction and explain it using the energy of the molecules and the bonds that break.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

If the catalyst temperature is higher, then more gas will be collected in 120 s, because the alkane molecules have more kinetic energy. More of their collisions with the catalyst surface have at least the activation energy needed to break C–C bonds, so more long molecules crack into short gaseous molecules each second.
Higher temperature, more gas; more molecules have the activation energy to break C–C bonds.

Mark yourself

94.4
B2 Level 3–4
[2]Drag each reason to the control variable it explains.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Mass of catalyst: more catalyst gives more surface. Size of pieces: smaller pieces have a larger surface area for cracking. Collection time: the same 120 s so the volumes can be compared.
t1 r3; t2 r1; t3 r2

Mark yourself

94.5
B1 Level 3–4
[1]In test runs, 300 °C gives less than 1 cm³ of gas in 120 s, and 700 °C fills the 100 cm³ syringe before 120 s. Select the best plan for Eszter's main runs.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark

Model answer

Six temperatures from 350 to 600 °C cover the range where the volume is measurable but the syringe does not overflow, and three runs each allow anomalies to be spotted and means to be found.
Option a.

Mark yourself

94.6
B1 Level 3–4
[1]Eszter's teacher later demonstrates real cracking, collecting the gas over water. Select the hazard that is specific to this experiment, with its precaution.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark

Model answer

When heating stops, the gas in the tube contracts and cold water can be sucked back up the delivery tube into the hot boiling tube, which may crack or shatter it. The delivery tube is lifted out of the water before the Bunsen burner is turned off, and eye protection is worn.
Option d.

Mark yourself

94.7
C2 Level 5–6
[2]These are Eszter's results. | Catalyst temperature (°C) | Run 1 volume (cm³) | Run 2 volume (cm³) | Run 3 volume (cm³) | |---|---|---|---| | 350 | 4.2 | 3.8 | 4.0 | | 400 | 8.8 | 9.4 | 9.1 | | 450 | 17.2 | 16.6 | 22.9 | | 500 | 27.5 | 28.6 | 28.1 | | 550 | 43.0 | 42.2 | 43.5 | | 600 | 60.4 | 61.8 | 61.1 | One result is anomalous. Calculate the mean volume at 450 °C, leaving out the anomaly. Give your answer to 1 decimal place.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

22.9 cm³ is about 6 cm³ above the other two runs, so it is anomalous. Mean = (17.2 + 16.6) ÷ 2 = 16.9 cm³
16.9 cm³

Mark yourself

94.8
C2 Level 5–6
[2]Use the graph in the introduction to find the mean rate of gas production at 650 °C between 20 s and 80 s. Give your answer in cm³/s to 2 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

From the graph, the volume is about 4 cm³ at 20 s and about 52 cm³ at 80 s. Rate = (52 − 4) ÷ (80 − 20) = 48 ÷ 60 = 0.80 cm³/s
About 0.80 cm³/s

Mark yourself

94.9
C3 Level 7–8
[3]Discuss whether Eszter's results support your hypothesis from part 94.3. Use values from the table in part 94.7, describe how the increase changes with each 50 °C step, and say whether the volume is proportional to the temperature.
Markscheme · 3 marks

Model answer

The results support the hypothesis. The mean volume of gas rose from about 4.0 cm³ at 350 °C to 9.1, 16.9, 28.1 and 42.9 cm³, reaching 61.1 cm³ at 600 °C. Each 50 °C step added more gas than the one before, about 5, 8, 11, 15 and then 18 cm³, so a graph would curve upwards. The volume is not proportional to the temperature: 600 °C is less than twice 350 °C, but about 15 times as much gas was made. This fits the idea that the fraction of molecules with at least the activation energy rises more and more quickly as the temperature goes up.
94.10
C3 Level 7–8
[3]Evaluate Eszter's method. Your answer should: name one random error and one systematic error that could occur in a real version of this experiment; suggest an improvement linked to a weakness you name; suggest an extension investigation.
Markscheme · 3 marks

Model answer

In a real version, a random error is that the paraffin is heated by hand, so the rate at which vapour reaches the catalyst varies from run to run. A systematic error is that the first gas collected is air pushed out of the tube, so every volume is slightly too large. Eszter could discard the first few cubic centimetres of gas before starting the 120 s, which removes the air, and use an electric heater with a temperature probe in the catalyst so the temperature is steady. As an extension she could investigate how the size of the catalyst pieces affects the volume of gas made at 500 °C.
Solves
0
Average rating
–
Open reports
0

Assessment criteria

A
Knowing and understanding
B
Inquiring and designing
C
Processing and evaluating
D
Reflecting on the impacts of science

Quality checks

  • Created by our AI question engine
  • Every number checked by script
  • Published for students