Rhys volunteers with a river trust that checks whether a stream is healthy enough for brown trout. Trout need at least about 7 mg of dissolved oxygen per dm³ of water to grow and breed well. For dilute solutions in water, 1 mg/dm³ is the same as 1 part per million (ppm) by mass.
The table shows the maximum mass of oxygen that can dissolve in fresh water in contact with air (the saturation value), based on published data.
| Water temperature (°C) | 0 | 10 | 20 | 30 |
|---|---|---|---|---|
| Oxygen at saturation (mg/dm³) | 14.6 | 11.3 | 9.1 | 7.6 |
On a warm afternoon the water is at 20 °C and Rhys's meter shows 6.4 mg/dm³ of dissolved oxygen.
Data you need
| Quantity | Value |
|---|---|
| relative atomic mass of O | 16 |
| volume of one mole of any gas at room temperature and pressure | 24 dm³ |
| 1 m³ | 1000 dm³ |
57.1
[1]Select the trend shown by the table.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
The saturation value falls from 14.6 mg/dm³ at 0 °C to 7.6 mg/dm³ at 30 °C: gases are less soluble in warmer water.
Less oxygen dissolves as the temperature rises.
Mark yourself
57.2
[2]The percentage saturation is the measured oxygen as a percentage of the saturation value at that temperature. Calculate the percentage saturation of the stream. Give your answer to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Percentage saturation = 6.4 ÷ 9.1 × 100 = 70.33… = 70.3%
70.3%
Mark yourself
57.3
[2]A trout farm has a tank holding 12.0 m³ of water at 10 °C, saturated with oxygen. Calculate the mass of dissolved oxygen, in g, in the tank. Give your answer to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Volume = 12.0 × 1000 = 12 000 dm³. Mass = 11.3 mg/dm³ × 12 000 dm³ = 135 600 mg = 135.6 g = 136 g (3 s.f.)
136 g
Mark yourself
57.4
[3]Rhys fills a 50.0 dm³ container with stream water at the time of his reading. If all the dissolved oxygen, $\mathrm{O_2}$, in it were collected as a gas, calculate its volume, in cm³ at room temperature and pressure. Give your answer to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks
Model answer
Mass of O₂ = 6.4 mg/dm³ × 50.0 dm³ = 320 mg = 0.320 g. Mᵣ(O₂) = 32, so moles = 0.320 ÷ 32 = 0.0100 mol. Volume = 0.0100 × 24 = 0.240 dm³ = 240 cm³
240 cm³
Mark yourself
57.5
[2]In winter the same stream is at 5 °C. Take the saturation value at 5 °C as halfway between the values at 0 °C and 10 °C, which is about 13 mg/dm³. Use this and the table to explain why trout in this stream are more at risk in summer than in winter.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Cold water can hold more dissolved oxygen: at 5 °C the saturation value is about 13 mg/dm³ (halfway between 14.6 and 11.3), well above the 7 mg/dm³ trout need. At 20 °C it is only 9.1 mg/dm³, so even a small loss of oxygen takes the level below 7 mg/dm³; Rhys's reading of 6.4 mg/dm³ is already too low.
Warm water holds less oxygen, so in summer the level falls below the 7 mg/dm³ trout need (6.4 mg/dm³ measured).
Mark yourself
57.6
[3]A factory upstream wants permission to release its clean but warm cooling water into the stream. Evaluate whether permission should be given, using the data and your own knowledge.
Markscheme · 3 marks
Model answer
The water may be clean, but heat is still a pollutant. The table shows that warmer water holds less oxygen: saturation falls from 9.1 mg/dm³ at 20 °C to 7.6 mg/dm³ at 30 °C, close to the 7 mg/dm³ trout need, and the stream is already at only 6.4 mg/dm³ on a warm day. Warmer water also makes organisms respire faster, so oxygen is used up more quickly. On the other hand, the factory may provide local jobs, and its water contains no added chemicals. I think permission should only be given if the factory first cools the water, for example in a cooling pond, so that it enters the stream at nearly the same temperature, and if the oxygen level is monitored continuously.