When strips of two different metals dip into salt solution and are joined to a voltmeter, they make a simple cell. Atoms of the more reactive metal lose electrons and become positive ions, and the electrons flow through the wire towards the less reactive metal, so a voltage is measured. For example, with magnesium and copper:
$\mathrm{Mg(s) \rightarrow Mg^{2+}(aq) + 2e^-}$
Oluwaseun wants to use simple cells to compare metals. He has strips of magnesium, aluminium, zinc, iron, nickel and copper, emery paper, a beaker, table salt, a digital voltmeter reading to 0.01 V and two leads with crocodile clips. This is his first plan:
I will rub the copper strip with emery paper. I will stir a spoonful of salt into some tap water in the beaker.
Then I will dip the copper strip and one of the other metals into the salt water, connect them to the voltmeter
and write down the voltage. The strips in the tray are different widths, so I will just use whichever one comes
out first. I will test each metal once.
104.1
[2]Select two weaknesses in Oluwaseun's first plan that would make his comparison of the metals unfair.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
The strength of the salt solution is not controlled, and only the copper is cleaned, so oxide layers may remain on some of the other metals.
b, d
Mark yourself
104.2
[1]Select the best research question for Oluwaseun's investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
How does the position in the reactivity series of the metal paired with copper affect the voltage of the cell? It names the independent variable (the metal, by its reactivity) and the dependent variable (voltage).
Option c.
Mark yourself
104.3
[1]Select the correct independent and dependent variables for Oluwaseun's investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
The independent variable is the metal paired with copper; the dependent variable is the voltage of the cell, in volts.
Option d.
Mark yourself
104.4
[2]Write a hypothesis for Oluwaseun's investigation. Give a prediction and explain it using what happens to the atoms of the metals.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
If the metal paired with copper is higher in the reactivity series, then the voltage will be larger, because atoms of a more reactive metal lose their outer electrons more easily, so there is a bigger difference between the two metals in how readily they give up electrons, and a bigger push on the electrons through the wire.
More reactive metal, larger voltage; its atoms lose electrons more readily than copper's.
Mark yourself
104.5
[2]Oluwaseun rewrites his plan. Drag each reason to the control variable it explains.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Copper every time: the voltage depends on both metals, so only one may change. Temperature: it affects how readily the metal atoms lose electrons. Same voltmeter: two meters can differ slightly.
t1 r1; t2 r2; t3 r3
Mark yourself
104.6
[2]The voltmeter has a red terminal marked V and a black terminal marked COM; it shows a positive reading when electrons enter at COM. Write a method step for setting up each cell so that the voltmeter shows a positive reading and a true voltage.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Clip the copper strip to the red (V) terminal and the other metal to the black (COM) terminal, because electrons flow out of the more reactive metal. Stand the two strips in the solution a few centimetres apart so that they do not touch each other.
Copper to red (V), the other metal to black (COM); keep the strips apart so they do not touch.
Mark yourself
104.7
[1]Select the hazard and precaution that best fit Oluwaseun's investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
Nickel is a common skin allergen and can cause contact dermatitis, so the nickel strip is handled with gloves or tongs, and hands are washed after the practical.
Option c.
Mark yourself
104.8
[2]These are Oluwaseun's results with his improved plan. The metals are listed in order of reactivity, most reactive first.
| Metal paired with copper | Run 1 voltage (V) | Run 2 voltage (V) | Run 3 voltage (V) |
|---|---|---|---|
| magnesium | 1.62 | 1.66 | 1.64 |
| aluminium | 0.62 | 0.55 | 0.60 |
| zinc | 0.88 | 0.90 | 0.89 |
| iron | 0.48 | 0.46 | 0.61 |
| nickel | 0.12 | 0.14 | 0.13 |
One iron result is anomalous. Calculate the mean voltage for iron, leaving out the anomaly. Give your answer to 2 decimal places.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
0.61 V is much higher than the other two iron runs, so it is anomalous. Mean = (0.48 + 0.46) ÷ 2 = 0.47 V
0.47 V
Mark yourself
104.9
[2]In one extra run, Oluwaseun left the magnesium–copper cell connected and read the voltmeter every 30 s.
| Time after dipping (s) | 30 | 60 | 90 | 120 | 150 | 180 |
|---|---|---|---|---|---|---|
| Voltage (V) | 1.66 | 1.63 | 1.61 | 1.60 | 1.59 | 1.59 |
Plot these six readings, with time on the horizontal axis.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Points at (30, 1.66), (60, 1.63), (90, 1.61), (120, 1.60), (150, 1.59) and (180, 1.59): the voltage falls quickly at first, then levels off.
Six points plotted correctly.
Mark yourself
104.10
[4]Evaluate your hypothesis from part 104.4 and Oluwaseun's improved method. Your answer should: judge the hypothesis using mean voltages from the table in part 104.8, including any metal that does not fit; explain that metal's result; use your graph from part 104.9 to name a weakness in when the readings are taken, and suggest an improvement linked to it; suggest an extension.
Markscheme · 4 marks
Model answer
The hypothesis is mostly supported. The mean voltage fell with reactivity: 1.64 V with magnesium, 0.89 V with zinc, 0.47 V with iron and 0.13 V with nickel. Aluminium does not fit, because its mean of 0.59 V is below zinc's even though aluminium is more reactive. This is because aluminium is covered by a thin, tough oxide layer that re-forms almost as soon as it is cleaned, so fewer aluminium atoms can lose electrons into the solution. My graph shows a weakness in timing: the magnesium cell fell from 1.66 V at 30 s to 1.59 V at 150 s, so readings taken at different times after dipping are not comparable. Oluwaseun should read every cell at the same fixed time, for example 30 s after dipping. As an extension he could investigate how the concentration of the salt solution affects the voltage of the zinc–copper cell.