The Mensah family are having their kitchen rewired. The electrician, Ms Novak, explains that all the kitchen sockets are on one circuit, protected in the consumer unit by a 32 A circuit breaker. The circuit also passes through a residual current device (RCD), which switches the supply off if the currents in the live and neutral wires differ by more than 30 mA.
The mains supply is 230 V. Power ratings of some of the family's appliances:
| Appliance | Power |
|---|---|
| kettle | 3.0 kW |
| toaster | 1.2 kW |
| dishwasher | 2.0 kW |
| washing machine | 2.2 kW |
| electric oven | 2.8 kW |
Useful equations
| To find | Use |
|---|---|
| power | power = potential difference × current ($P = VI$) |
| power transferred to a resistance | power = current² × resistance ($P = I^2R$) |
53.1
[2]Select two advantages of a circuit breaker compared with a fuse.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
A circuit breaker can simply be reset once the fault is fixed, and it cuts off the current faster than a fuse wire can melt.
b and e
Mark yourself
53.2
[2]Calculate the current in the kettle when it is switched on. Give your answer in amperes to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
I = P ÷ V = 3000 ÷ 230 = 13.0 A (3 s.f.)
13.0 A
Mark yourself
53.3
[3]On Sunday morning all five appliances in the table are switched on at the same time, on the kitchen socket circuit. Determine the total current in the circuit, and state whether the 32 A circuit breaker trips. Give the current in amperes to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks
Model answer
Total power = 3.0 + 1.2 + 2.0 + 2.2 + 2.8 = 11.2 kW = 11 200 W. I = 11 200 ÷ 230 = 48.7 A (3 s.f.). This is well above the 32 A rating (about 1.5 times it), so the circuit breaker trips.
48.7 A; yes, it trips.
Mark yourself
53.4
[2]A person touches a damaged cable and some current flows from the live wire through their body to the ground. Explain how the RCD protects them.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Some of the current leaves through the live wire and returns through the person to the ground instead of through the neutral wire. So the current in the neutral is less than in the live. When the difference is more than 30 mA, the RCD detects it and switches off the supply very quickly, before a dangerous current flows for long.
It detects that the live and neutral currents differ and quickly switches off the supply.
Mark yourself
53.5
[2]The cable from the consumer unit to the kitchen sockets and back has a total resistance of 0.30 Ω. Calculate the power wasted heating the cable when the current in it is 30 A. Give an exact answer, in watts.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
P = I²R = 30² × 0.30 = 900 × 0.30 = 270 W
270 W
Mark yourself
Key idea. Heating in a cable grows with the square of the current, which is why circuits carrying large currents need thicker cables and a correctly rated circuit breaker.