✦ Created by our AI question engine · answers checked by script
Self-marked 0 / 9
How this page works
Full help
- Read the question and the information above the parts.
- Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
- Check your final line with Check my answer. Use the calculator on the right when you need it.
- Mark yourself: open the markscheme and tick each mark you earned.
Oluwaseun's grandfather runs a model railway in his garage. The controller plugs into the 230 V a.c. mains and contains a transformer that steps the voltage down for the track.
- Number of turns on the primary coil: 2300
- Number of turns on the secondary coil: 120
- The coils are wound on a laminated iron core.
Useful equations
| To find | Use |
|---|---|
| p.d. or number of turns (any transformer) | $\frac{V_p}{V_s} = \frac{N_p}{N_s}$ |
| p.d. or current (100% efficient transformer) | $V_p I_p = V_s I_s$ |
5.1
[2]The railway's signals use small electromagnets to move the signal arms. Select two changes that would make an electromagnet stronger.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
More turns and a larger current both make the magnetic field stronger.
More turns; larger current.
Mark yourself
5.2
[2]Explain why the transformer would not work if it were connected to a direct current (d.c.) supply.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
A p.d. is induced in the secondary coil only when the magnetic field in the core is changing. Alternating current makes the field change continuously. A steady direct current makes a constant field, so no p.d. is induced in the secondary coil.
Only a changing magnetic field induces a p.d. in the secondary; d.c. gives a constant field.
Mark yourself
5.3
[2]Calculate the output voltage of the transformer.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
V_s = V_p × N_s ÷ N_p = 230 × 120 ÷ 2300 = 12 V
12 V
Mark yourself
5.4
[3]The train draws a current of 1.5 A from the secondary coil. Assume the transformer is 100% efficient. Calculate the current in the primary coil. Give your answer in mA to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks
Model answer
Power out = 12 × 1.5 = 18 W. Power in = 230 × I_p = 18, so I_p = 18 ÷ 230 = 0.0783 A = 78.3 mA.
78.3 mA
Mark yourself
5.5
[3]In the National Grid, step-up transformers raise the voltage to hundreds of thousands of volts before electricity is sent along power cables. Explain why this is done and one benefit it brings to society or the environment.
Markscheme · 3 marks
Model answer
For the same power, P = VI, so raising the voltage lowers the current in the cables. The cables have resistance and heat up more when the current is larger, so a lower current wastes less energy as heat. Because less energy is lost, power stations need to generate less, which saves fuel, lowers bills and reduces carbon dioxide emissions.