An energy company plans a pumped-storage hydroelectric station in the Scottish Highlands. It has two lakes, one high on a hillside and one in the glen below, joined by a tunnel. When demand for electricity is high, water flows down the tunnel and turns turbines that drive generators. At night, when electricity is cheap and wind farms often produce more than is needed, the same machines work as pumps and push water back up to the high lake.
Figures for the planned station (simplified):
| Quantity | Value |
|---|---|
| height of the high lake's surface above the turbines | 400 m |
| volume of water flowing through the turbines each second at full power | 120 m³ |
| efficiency of the turbines and generators together | 90% |
| density of water | 1000 kg/m³ |
| gravitational field strength, $g$ | 9.8 N/kg |
Useful equations
| To find | Use |
|---|---|
| mass | mass = density × volume ($m = \rho V$) |
| change in gravitational potential energy | $\Delta E_p = mg\Delta h$ |
| power | power = energy transferred ÷ time |
| efficiency | efficiency = useful output ÷ total input |
| energy transferred (MWh) | energy (MWh) = power (MW) × time (h) |
49.1
[2]Drag the energy store that is largest or increasing to each stage. Two stores are not used.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Water high up: gravitational potential store. Moving water: kinetic store. Warm bearings: thermal store. The chemical and elastic stores are not used.
t1 gravitational, t2 kinetic, t3 thermal
Mark yourself
49.2
[2]Calculate the mass of water flowing through the turbines each second at full power. Give an exact answer in kg.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
m = ρV = 1000 × 120 = 120 000 kg
120 000 kg
Mark yourself
49.3
[3]Calculate the electrical power output of the station at full power. Give your answer in MW to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks
Model answer
Energy lost by the falling water each second = mgh = 120 000 × 9.8 × 400 = 470 400 000 J, so the input power is 470.4 MW. Output = 0.90 × 470.4 = 423.36 MW ≈ 423 MW (3 s.f.)
423 MW
Mark yourself
49.4
[2]One evening the station generates at full power for 5.0 hours. Pumping that water back up to the high lake overnight uses 2800 MWh of electrical energy. Calculate the overall efficiency of storing energy in the station, as a percentage. Give your answer to 2 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Energy generated = 423.36 MW × 5.0 h = 2116.8 MWh. Overall efficiency = 2116.8 ÷ 2800 × 100 = 75.6% ≈ 76% (2 s.f.)
76%
Mark yourself
49.5
[3]A local resident objects: "This station uses more electricity than it produces, so it is a waste of money." Evaluate this view. Consider how the station helps the electricity supply, as well as its impacts on the glen.
Markscheme · 3 marks
Model answer
The resident is correct that only about 76% of the energy used for pumping comes back as electricity. However, the station is a store, not a source. It takes in electricity at night, when wind farms often produce more than is needed and it would otherwise be wasted, and gives it back in the evening when demand is highest, so fewer gas power stations have to run. It can also reach full power within minutes if demand suddenly rises. Against this, building the dam and tunnel would damage habitats and change a wild landscape, and the high lake's level would rise and fall each day. On balance I disagree with the resident: storing renewable energy is valuable, as long as the construction is carefully managed.