Sign in
United Kingdom › MYP Physics › Energy, work and power
Question

Replacing a Gas Power Station

A6 · C3 · D4 · 13 marks · ~17 min
✦ Created by our AI question engine · answers checked by script Self-marked 0 / 9
How this page works Full help
  1. Read the question and the information above the parts.
  2. Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
  3. Check your final line with Check my answer. Use the calculator on the right when you need it.
  4. Mark yourself: open the markscheme and tick each mark you earned.

An older gas-fired power station on an estuary in northern England is due to close. The regional council is comparing it with a proposed group of offshore wind farms.

Sankey diagram data for the gas power station, per second:

  • Energy supplied by burning natural gas: 1200 MJ (an input power of 1200 MW)
  • Useful electrical output: 540 MW
  • The rest is transferred to the surroundings, mainly by warm water from the cooling system and hot waste gases.

Each proposed wind farm has 40 turbines. Each turbine has a maximum output of 3.0 MW, but because the wind varies, over a year a turbine produces on average only 35% of its maximum output.

Efficiency = useful power output ÷ total power input.

12.1
A2 Level 1–2
[2]Select two renewable energy resources.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Tides and sunlight are renewable: they are replaced naturally as fast as we use them.
tides and sunlight

Mark yourself

12.2
A2 Level 3–4
[2]Calculate the efficiency of the gas power station, as a percentage.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Efficiency = 540 ÷ 1200 = 0.45 = 45%
45%

Mark yourself

12.3
A1 · C1 Level 3–4
[2]In a Sankey diagram the width of each arrow shows the power. Calculate the power shown by the wasted-energy arrow, in MW.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks

Model answer

Wasted power = total input − useful output = 1200 − 540 = 660 MW
660 MW

Mark yourself

12.4
A1 · C2 Level 5–6
[3]Determine the smallest whole number of wind farms needed to give, on average, at least the same electrical output as the gas power station.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks

Model answer

Average output of one wind farm = 40 × 3.0 × 0.35 = 42 MW. Number needed = 540 ÷ 42 = 12.86, so 13 wind farms (12 would give only 504 MW).
13 wind farms

Mark yourself

12.5
D4 Level 7–8
[4]Evaluate the proposal to replace the gas power station with offshore wind farms. Consider the environment, the reliability of the electricity supply and the local community, and give a justified conclusion.
Markscheme · 4 marks

Model answer

Replacing the gas station with offshore wind would cut carbon dioxide emissions, because wind turbines burn no fuel, whereas the gas station wastes 55% of the energy in its fuel. However, wind is variable: on average about 13 wind farms are needed to match the gas station, and on calm days output could be much lower, so batteries, pumped storage or some backup generation would still be needed. Building in the sea may disturb seabirds and marine life. Jobs at the gas station would be lost, but new jobs in building and maintaining the turbines could replace them. Overall I support the proposal if it includes storage and a gradual phase-out of gas, so the supply stays reliable.
Solves
0
Average rating
–
Open reports
0

Assessment criteria

A
Knowing and understanding
B
Inquiring and designing
C
Processing and evaluating
D
Reflecting on the impacts of science

Quality checks

  • Created by our AI question engine
  • Every number checked by script
  • Published for students