✦ Created by our AI question engine · answers checked by script
Self-marked 0 / 9
How this page works
Full help
- Read the question and the information above the parts.
- Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
- Check your final line with Check my answer. Use the calculator on the right when you need it.
- Mark yourself: open the markscheme and tick each mark you earned.
In Jonas's school, real radioactive sources are handled only by teachers, so Jonas uses a computer simulation of a laboratory. On screen, a beta source is placed 5.0 cm from a Geiger–Müller (GM) tube connected to a counter. He can slide aluminium sheets, each 0.5 mm thick, between the source and the tube. The simulation includes background radiation, which it says is 24 counts per minute, and like real decay, the counts are random.
Jonas counts for 1 minute at each thickness, three times.
| Aluminium thickness / mm | Count in 1 min, trial 1 | Trial 2 | Trial 3 |
|---|---|---|---|
| 0.0 | 990 | 975 | 1012 |
| 0.5 | 498 | 512 | 505 |
| 1.0 | 270 | 520 | 262 |
| 1.5 | 141 | 150 | 143 |
| 2.0 | 82 | 88 | 79 |
| 2.5 | 55 | 50 | 58 |
| 3.0 | 40 | 37 | 39 |
Jonas's note on trial 2 at 1.0 mm: "Forgot to stop the timer — it ran for 2 minutes."
Useful equations
| To find | Use |
|---|---|
| corrected count rate | mean count rate − background count rate |
76.1
[1]Select the best research question for this investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
How does the thickness of aluminium between a beta source and a GM tube affect the count rate? It names the independent variable (thickness) and the dependent variable (count rate).
a
Mark yourself
76.2
[2]Write a hypothesis for Jonas's investigation. Include a scientific reason.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
If the aluminium is thicker, then the count rate will be lower, because beta particles lose energy by ionising atoms as they pass through the aluminium, so more of them are absorbed before they reach the GM tube. Each extra 0.5 mm should absorb about the same fraction of the particles that reach it.
Thicker aluminium gives a lower count rate, because more beta particles are absorbed.
Mark yourself
76.3
[2]Select the three variables Jonas should keep the same.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Keep the source-to-tube distance (5.0 cm), the counting time (1 minute) and the source the same. Thickness is the independent variable; the count is the dependent variable.
distance; counting time; same source
Mark yourself
76.4
[1]Select the reason Jonas must take the background count rate into account.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
Background radiation, from rocks and buildings, radon in the air and cosmic rays, reaches the tube all the time. Its count rate must be subtracted to find the count rate due to the source alone.
b
Mark yourself
76.5
[2]Later, Jonas's teacher demonstrates the experiment with a real beta source. Identify the hazard and state a precaution the teacher should take.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Hazard: beta radiation is ionising, so it can damage cells and DNA in the body, which may lead to cancer. Precaution: handle the source with long tongs, keep it at arm's length pointing away from people, use it for as short a time as possible and return it straight to its lead-lined box.
Ionising radiation can damage cells; use tongs, keep it pointed away at arm's length, and minimise the time it is out.
Mark yourself
76.6
[3]Calculate the corrected count rate for 1.0 mm of aluminium. Leave out the anomaly, then allow for the background. Give your answer in counts per minute, exact.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks
Model answer
Trial 2 (520) was counted for 2 minutes, so leave it out. Mean = (270 + 262) ÷ 2 = 266 counts per minute. Corrected count rate = 266 − 24 = 242 counts per minute.
242 counts per minute
Mark yourself
76.7
[2]With no aluminium the corrected count rate is 968 counts per minute, and with 0.5 mm it is 481 counts per minute, so 0.5 mm roughly halves it. Assuming every 0.5 mm halves the corrected count rate, predict the corrected count rate for 3.0 mm. Give your answer to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
3.0 mm ÷ 0.5 mm = 6 half-value thicknesses. Corrected count rate = 968 × (½)⁶ = 968 ÷ 64 = 15.1 counts per minute (3 s.f.). The measured corrected value is 38.7 − 24 = 14.7, close to the prediction.
15.1 counts per minute
Mark yourself
76.8
[2]Jonas says: "The counter still shows about 39 counts per minute with 3.0 mm of aluminium, so most beta particles are still getting through." Explain why he is wrong, using the data.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
About 24 of the 39 counts per minute are background radiation, which would be there even with no source. Only about 39 − 24 = 15 counts per minute come from the source, compared with 968 with no aluminium, so only about 1.5% of the beta particles get through: almost all are absorbed.
24 of the counts are background; only about 15 per minute (≈1.5% of 968) come from the source.
Mark yourself
76.9
[4]Evaluate Jonas's investigation. Judge your hypothesis using corrected count rates, explain why the results at large thicknesses are the least reliable, suggest an improvement linked to that weakness, and comment on one limitation of using a simulation. Suggest one extension.
Markscheme · 4 marks
Model answer
The results support the hypothesis. After subtracting the background, the count rate falls from 968 counts per minute with no aluminium to 481 at 0.5 mm and 242 at 1.0 mm, roughly halving for every 0.5 mm, and is only about 15 at 3.0 mm. The results at large thicknesses are the least reliable: decay is random, so a count of about 40 can easily vary by 6 or more, which is over 15% of the reading, and 24 of the counts are background. Counting for 10 minutes at these thicknesses, and measuring the background for longer, would give larger counts and a smaller percentage uncertainty. A limitation is that the simulation can only show what it was programmed to do, so the results do not prove that real aluminium behaves like this; the teacher's demonstration with a real source would test it. As an extension, Jonas could use the simulation to see how lead absorbs gamma radiation.