Read the question and the information above the parts.
Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
Check your final line with Check my answer. Use the calculator on the right when you need it.
Mark yourself: open the markscheme and tick each mark you earned.
Some low-sodium "salt substitute" sold in supermarkets is almost pure potassium chloride. About 0.012% of potassium atoms are radioactive potassium-40, which decays mainly by giving out beta particles. Hamid uses a virtual lab to investigate the radiation from this salt substitute.
In the simulation he weighs out a mass of salt substitute, spreads it in an even layer over the bottom of a shallow dish 12 cm across, and places a Geiger–Müller (GM) tube 1.0 cm above the middle of the dish. He counts for 10 minutes, three times for each mass. The 0 g row is the empty dish, which gives the background. Like real decay, the counts vary randomly, and the simulation includes the absorption of beta particles by the salt itself.
Mass of salt substitute / g
Count in 10 min, run 1
Run 2
Run 3
Mean count rate / counts per min
0
196
205
199
20.0
2
322
311
327
32.0
4
407
423
418
41.6
8
554
540
531
54.2
12
641
637
322
?
16
691
710
702
70.1
20
731
721
742
73.1
Hamid's note: "12 g, run 3: I found afterwards that I had set the counter to 5 minutes by mistake."
The simulation's help page says that 1 g of this salt substitute has an activity of about 16 Bq (16 decays each second). Even 20 g makes a layer less than 2 mm deep in this dish.
Useful equations
To find
Use
count rate
count ÷ counting time
corrected count rate
count rate − background count rate
gradient of a straight-line graph
change in $y$ ÷ change in $x$
112.1
B1Level 1–2
[1]Select the best research question for Hamid's investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
How does the mass of salt substitute in the dish affect the corrected count rate? It names the independent variable (mass) and the dependent variable (corrected count rate).
a
Mark yourself
112.2
B2Level 3–4
[2]Write a hypothesis for Hamid's investigation. Include a scientific reason about the nuclei in the salt.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
If the mass of salt substitute is greater, then the corrected count rate will be higher; doubling the mass should double it. This is because more salt contains more potassium-40 nuclei, and each nucleus has the same chance of decaying each second, so more decays happen each second and more beta particles reach the tube.
More mass gives a higher corrected count rate (proportional), because there are more potassium-40 nuclei to decay.
Mark yourself
112.3
B1Level 1–2
[1]Select the correct independent and dependent variables, with their units.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
Independent variable: mass of salt substitute, in g. Dependent variable: the count rate caused by the salt alone (the corrected count rate), in counts per minute: the count ÷ 10 minutes, minus the background.
b
Mark yourself
112.4
B2Level 3–4
[2]Drag the reason to each control variable. One reason is not used.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Height of the tube: beta particles spread out and are absorbed by air, so moving the tube a little changes the count rate a lot. Counting time: the number of decays recorded is directly proportional to it. One brand: another brand may contain a different percentage of potassium, so the same mass would have a different activity. The background cannot be removed by controlling a variable; it must be measured (the 0 g row) and subtracted.
height — absorbed and spread out; time — proportional; brand — percentage of potassium
Mark yourself
112.5
B1Level 3–4
[1]Select the best reason for counting for 10 minutes, three times, at each mass.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
Decay is random, so counts vary from one run to the next. The count rates are only a few tens of counts per minute, so counting for 10 minutes collects hundreds of counts, which reduces the effect of the random variation, and three runs show the spread and reveal any anomaly.
d
Mark yourself
112.6
B2Level 3–4
[2]Write the method step Hamid should follow to prepare each sample before he starts counting.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Put the empty dish on a balance and press tare, then add salt substitute until the balance shows the chosen mass. Spread it into an even, flat layer over the whole bottom of the dish, and place the dish centred under the GM tube, with the tube 1.0 cm above it.
Weigh the salt on a tared balance, spread it evenly over the dish, and centre the dish under the tube.
Mark yourself
112.7
B2Level 3–4
[2]Hamid's teacher later lets the class repeat the experiment with real salt substitute and a real GM tube. The radiation dose from the salt is tiny. Identify one hazard in the real experiment that does matter, and state a precaution that reduces it.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Hazard: the powder could be swallowed or get into someone's eyes; potassium chloride stings the eyes, and swallowing a large amount is harmful to the heart (and would also put a radioactive substance inside the body). Precaution: no eating or drinking in the lab, handle the powder with a spatula, keep the dish covered when not counting, wear safety glasses, wipe up spills and wash hands afterwards.
Powder swallowed or in the eyes; no eating or drinking, spatula, cover the dish, safety glasses, wash hands.
Mark yourself
112.8
C3Level 5–6
[3]Calculate the corrected count rate for 12 g. Leave out the anomalous run. Give your answer in counts per minute to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks
Model answer
Leave out 322 (a 5-minute count). Mean count = (641 + 637) ÷ 2 = 639 in 10 minutes, so the count rate = 639 ÷ 10 = 63.9 counts per minute. Corrected count rate = 63.9 − 20.0 = 43.9 counts per minute.
43.9 counts per minute
Mark yourself
112.9
C2Level 5–6
[2]Hamid plots corrected count rate (table mean − 20.0) against mass. Calculate the gradient of the graph between the points for 16 g and 20 g. Give your answer in counts per minute per gram to 2 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Corrected rates: 73.1 − 20.0 = 53.1 and 70.1 − 20.0 = 50.1 counts per minute. Gradient = (53.1 − 50.1) ÷ (20 − 16) = 3.0 ÷ 4 = 0.75 counts per minute per gram. (Subtracting the background does not change the gradient.)
0.75 counts per minute per gram
Mark yourself
112.10
B1 · C3Level 7–8
[4]Evaluate Hamid's investigation. Use numbers to judge your hypothesis, including whether the corrected count rate is proportional to mass (compare the gradient between 0 g and 2 g with your gradient between 16 g and 20 g); explain why the graph levels off; comment on the random variation; use the help-page activity to estimate the percentage of decays from 20 g that the tube detects; and suggest an improvement linked to a weakness.
Markscheme · 4 marks
Model answer
The results only partly support the hypothesis. The corrected count rate does rise with mass, from 12.0 counts per minute for 2 g to 53.1 for 20 g, but it is not proportional: the gradient is 12.0 ÷ 2 = 6.0 counts per minute per gram between 0 and 2 g, but only 0.75 between 16 and 20 g, and the graph levels off. This is because the salt absorbs its own beta particles. All the salt is in the same dish, so extra salt makes the layer thicker, and beta particles from the bottom of the layer are absorbed by the salt above before they reach the tube. Only a thin top layer adds to the count, so once the layer passes a fraction of a millimetre, more salt adds very little. The random variation is also important: a count of about 730 varies by about √730 ≈ 27, about 4%, and the 20 g runs range from 721 to 742, so the small rise between 16 g and 20 g is hard to measure. The tube detects only a tiny fraction of the decays: 20 g has an activity of about 320 Bq, which is 19 200 decays per minute, but only 53.1 counts per minute are detected, about 0.3%. To test whether the count rate is proportional to the amount of potassium-40, Hamid should keep the layer very thin and change the area instead, spreading each mass over a larger tray, and count for longer at the higher masses.
Your feedback
Rate this question
How hard was it?
Saved for this browser only; no account needed. You can change your rating or vote at any time.