Read the question and the information above the parts.
Write your working and your answer in the box for each part, with units, as in the exam. Press Enter for a new line.
Check your final line with Check my answer. Use the calculator on the right when you need it.
Mark yourself: open the markscheme and tick each mark you earned.
Kwame uses an online virtual laboratory, because students in his school may not handle radioactive sources. The simulation shows a cobalt-60 gamma source in a small holder and a Geiger–Müller (GM) tube on a straight track marked in centimetres. Kwame measures the distance from the front face of the source holder to the front of the GM tube. The simulation adds a background count rate of 20 counts per minute and, like real decay, gives counts that vary randomly.
At each distance Kwame records the count in 1 minute three times. These are his raw results.
Distance / cm
Count in 1 min, trial 1
Trial 2
Trial 3
Mean count rate / counts per min
10
1608
1641
1612
1620
15
770
789
769
776
20
452
466
459
459
25
311
298
309
306
30
226
214
223
221
40
131
139
198
?
Kwame's note: "40 cm, trial 3 — I found I had left a second source from an earlier task on the virtual bench."
The simulation's help page says that the radioactive material sits 1.0 cm behind the front face of the holder.
Useful equations
To find
Use
corrected count rate, $C$
mean count rate − background count rate
inverse square model for gamma rays
$C = \dfrac{k}{d^2}$, where $d$ is the distance from the radioactive material and $k$ is a constant
94.1
B1Level 1–2
[1]Select the best research question for Kwame's investigation.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
How does the distance between a gamma source and a GM tube affect the corrected count rate? It names the independent variable (distance) and the dependent variable (corrected count rate).
a
Mark yourself
94.2
B2Level 3–4
[2]Write a hypothesis for Kwame's investigation. Include a scientific reason about how gamma rays travel from the source.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
If the GM tube is further from the source, then the corrected count rate will be lower; doubling the distance should make it about a quarter (inverse square law). This is because the gamma rays spread out in all directions, so the same number of rays is spread over a sphere whose area grows with the distance squared, and very few are absorbed by the air.
Count rate falls with distance (inverse square), because the gamma rays spread out over a larger area.
Mark yourself
94.3
B1Level 1–2
[1]Select the correct independent and dependent variables, with units.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
Independent variable: distance from the source, in cm (Kwame chooses it). Dependent variable: corrected count rate, in counts per minute (measured, then the background is subtracted).
b
Mark yourself
94.4
B2Level 3–4
[2]Drag the reason to each control variable. One reason is not used.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Counting time: a longer count records more decays, so every count lasts 1 minute. Source: a different source has a different activity. Gap: anything between the source and the tube would absorb some gamma rays. The background is the same everywhere along the track (20 counts per minute), so that reason is false.
time — same counting time; source — activity; gap — absorption
Mark yourself
94.5
B1Level 3–4
[1]Select the best reason for recording three counts at each distance.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 1 mark
Model answer
Decay is random, so the count changes from one minute to the next; three counts show the spread, help to spot an anomaly and give a more reliable mean.
a
Mark yourself
94.6
B2Level 3–4
[2]Kwame's teacher later shows the effect with a real cobalt-60 source. Identify the hazard and state a precaution the teacher should take.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 2 marks
Model answer
Hazard: gamma rays are ionising and very penetrating, so they can pass into the body and damage cells and DNA, which may cause cancer. Precaution: lift the source only with long tongs, keep it pointed away from people and at a distance, keep the class well back, use it for as short a time as possible and lock it back in its lead-lined box.
Ionising gamma rays can damage cells/DNA; use tongs, keep distance, point it away, minimise time, return it to its lead box.
Mark yourself
94.7
C3Level 5–6
[3]Calculate the corrected count rate at 40 cm. Leave out the anomalous trial. Give your answer in counts per minute, exact.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
Markscheme · 3 marks
Model answer
Leave out 198 (second source on the bench). Mean = (131 + 139) ÷ 2 = 135 counts per minute. Corrected count rate = 135 − 20 = 115 counts per minute.
115 counts per minute
Mark yourself
94.8
C2Level 5–6
[2]Kwame plots corrected count rate against $1/d^2$, using his measured distances. Calculate the gradient of the line between the points for 20 cm and 30 cm. Give your answer in counts per minute × cm² to 3 significant figures.
Checks your final line. Mark a different line with ★ if your answer is not the last line.
[4]Evaluate Kwame's investigation. Test the inverse square model by working out $C \times d^2$ at 10 cm and at 40 cm, and judge your hypothesis; explain which error the help-page note causes and whether it is random or systematic; explain why the far readings are the least precise; suggest an improvement linked to a weakness; and comment on one limitation of using a simulation.
Markscheme · 4 marks
Model answer
The corrected count rate falls from 1600 counts per minute at 10 cm to 115 at 40 cm, so the rate does fall with distance as I predicted. However, C × d² is about 1600 × 10² = 160 000 at 10 cm but 115 × 40² = 184 000 at 40 cm, so the measured distances do not fit the inverse square model exactly. The help-page note explains why. Kwame measured from the front of the holder, but the radioactive material is 1.0 cm further back, so every true distance is 1.0 cm larger than recorded. This is a systematic (zero) error: it is the same in every reading and affects the short distances most (10% at 10 cm, but only 2.5% at 40 cm). Using d + 1.0 cm gives 1600 × 11² ≈ 194 000 and 115 × 41² ≈ 193 000, which agree, so the inverse square law fits well. The readings at 40 cm are the least precise, because decay is random and the counts are small: about 135 per minute varies by about ±12, around 9%, and 20 of those counts are background. Kwame should add 1.0 cm to each distance and count for 5 or 10 minutes at the larger distances. Finally, a simulation only follows the rules it was programmed with, so his teacher's demonstration with a real source is needed to show that real gamma rays behave this way.